NSN 6680-00-232-6708
Part Details | FLOW RATE INDICATING METER
6680-00-232-6708 An instrument for measuring the rate of flow of a fluid through a pipeline. This measurement is indicated on a graduated scale either by means of a float confined in a tube, or pointer connected to a vane, or piston and spring or the like. Excludes METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: M025, 6680-00-232-6708, 00-232-6708, 6680002326708, 002326708
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | OCT 24, 1970 | 00-232-6708 | 38346 ( METER, FLOW RATE INDICATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-232-6708
Part Number | Cage Code | Manufacturer |
---|---|---|
M025 | 12854 | SIERRA FIRE EQUIPMENT CO |
Technical Data | NSN 6680-00-232-6708
Characteristic | Specifications |
---|---|
DESIGN TYPE | CASE |
SCALE QUANTITY | 1 |
DIAL SCALE MARKING RANGE | P200.0/P1500.0 |
DIAL SCALE REFERENCE POINTER | NOT INCLUDED |
METER TYPE | FLOAT |
INLET CONNECTION TYPE | ANY ACCEPTABLE |
INLET CONNECTION POSITION FOR WHICH DESIGNED | HORIZONTAL |
OUTLET CONNECTION TYPE | ANY ACCEPTABLE |
OUTLET CONNECTION POSITION FOR WHICH DESIGNED | HORIZONTAL |
INTEGRAL RELIEF VALVE | NOT INCLUDED |
INTEGRAL HEAT SOURCE | NOT INCLUDED |
ALARM SIGNAL | NOT INCLUDED |
CONSTRUCTION | HN ANY ACCEPTABLE |
BASE | INCLUDED |
CARRYING HANDLE | NOT INCLUDED |
SCALE TYPE | DIRECT CAPACITY READING |
MEDIA FOR WHICH DESIGNED | WATER |
SCALE MARKING | GPM |
DIAL SCALE SMALLEST INCREMENT | 200.GPM |
UNIT TYPE | PORTABLE |
INLET CONNECTION DEVICE TYPE | SWIVEL |