NSN 6680-01-242-4827
Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-01-242-4827 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 02PHXXX0X20A1BXXBX01, 02PHXXX0X20A1BXXBX, 6680-01-242-4827, 01-242-4827, 6680012424827, 012424827
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | OCT 12, 1986 | 01-242-4827 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-242-4827
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 02PHXXX0X20A1BXXBX01 | 05991 | CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS |
| 02PHXXX0X20A1BXXBX | 05991 | CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS |
Technical Data | NSN 6680-01-242-4827
| Characteristic | Specifications |
|---|---|
| MEDIA FOR WHICH DESIGNED | WATER |
| PRESSURE TYPE | K$J |
| MAXIMUM DIFFERENTIAL PRESSURE | 0 TO 20 INCHES OF WATER COLUMN |
| SCALE PRESENTATION RANGE | 0 TO 50 RANGE OF NUMERICAL MARKINGS |
| CASE MATERIAL | ALUMINUM |
| CASE SHAPE | ROUND |
| INLET CONNECTION SIZE | 1/4 IN. 18 THD NPT |
| OUTLET CONNECTION SIZE | 1/2 IN. 14 THD NPT |