NSN 6680-01-277-5975

Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER

6680-01-277-5975 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Alternate Parts: 20BGXXX0446A4CBAXX01, 6680-01-277-5975, 01-277-5975, 6680012775975, 012775975

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66APR 24, 198801-277-597508249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-277-5975
Part Number Cage Code Manufacturer
20BGXXX0446A4CBAXX0105991CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS
Technical Data | NSN 6680-01-277-5975
Characteristic Specifications
MEDIA FOR WHICH DESIGNED WATER
PRESSURE TYPEK$J
MAXIMUM DIFFERENTIAL PRESSURE446.0 RANGE OF NUMERICAL MARKINGS
SCALE PRESENTATION RANGE0 TO 446 IN. OF WATER COLUMN
CASE MATERIAL ALUMINUM, CAST