NSN 6680-01-285-3374

Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER

6680-01-285-3374 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Alternate Parts: 06ABXXX0129A5BXXXX01, 6680-01-285-3374, 01-285-3374, 6680012853374, 012853374

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66SEP 10, 198801-285-337408249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-285-3374
Part Number Cage Code Manufacturer
06ABXXX0129A5BXXXX0105991CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS
Technical Data | NSN 6680-01-285-3374
Characteristic Specifications
MEDIA FOR WHICH DESIGNED WATER
PRESSURE TYPEK$J
MAXIMUM DIFFERENTIAL PRESSURE129.0 IN. OF WATER COLUMN
SCALE PRESENTATION RANGE0 TO 129 RANGE OF NUMERICAL MARKINGS
SCALE INSCRIPTION/BACKGROUND COLORBLACK MARKINGS ON WHITE BACKGROUND
TOTALIZING INTEGRATOR REGISTER NOT INCLUDED
CASE MATERIAL ALUMINUM, CAST
CASE SHAPE ROUND
MOUNTING TYPED ANY ACCEPTABLE
INLET CONNECTION SIZE1/4 IN. 18 THD NPT
OUTLET CONNECTION SIZE1/4 IN. 18 THD NPT