NSN 6680-01-288-9805

Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER

6680-01-288-9805 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Alternate Parts: 20HCXXX0178A5BBAXX01, 6680-01-288-9805, 01-288-9805, 6680012889805, 012889805

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66NOV 17, 198801-288-980508249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-288-9805
Part Number Cage Code Manufacturer
20HCXXX0178A5BBAXX0105991CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS
Technical Data | NSN 6680-01-288-9805
Characteristic Specifications
MEDIA FOR WHICH DESIGNED WATER
PRESSURE TYPEK$J
MAXIMUM DIFFERENTIAL PRESSURE178.0 INCHES OF WATER COLUMN
SCALE PRESENTATION RANGE0 TO 178 RANGE OF NUMERICAL MARKINGS
TOTALIZING INTEGRATOR REGISTER NOT INCLUDED
CASE MATERIAL ALUMINUM, CAST
CASE SHAPE ROUND
MOUNTING TYPED ANY ACCEPTABLE
INLET CONNECTION SIZE7/16 IN. 20 THD UNF
OUTLET CONNECTION SIZE7/16 IN. 20 THD UNF