NSN 6680-01-300-4833

Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER

6680-01-300-4833 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Alternate Parts: 20YCXXX0100A4CBAXX01, 6680-01-300-4833, 01-300-4833, 6680013004833, 013004833

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66MAY 14, 198901-300-483308249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-300-4833
Part Number Cage Code Manufacturer
20YCXXX0100A4CBAXX0105991CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS
Technical Data | NSN 6680-01-300-4833
Characteristic Specifications
MEDIA FOR WHICH DESIGNED WATER
PRESSURE TYPEK$J
MAXIMUM DIFFERENTIAL PRESSURE100.0 IN. OF WATER COLUMN
SCALE PRESENTATION RANGE0 TO 100 RANGE OF NUMERICAL MARKINGS
CASE MATERIAL ALUMINUM
MOUNTING TYPED ANY ACCEPTABLE
INLET CONNECTION SIZE7/16 IN. 20 THD UNF
OUTLET CONNECTION SIZE7/16 IN. 20 THD UNF
SPECIAL FEATURESBLANK WHITE DIAL; RED SET POINTER