NSN 6680-01-312-0799

Part Details | FLOW RATE INDICATING METER

6680-01-312-0799 An instrument for measuring the rate of flow of a fluid through a pipeline. This measurement is indicated on a graduated scale either by means of a float confined in a tube, or pointer connected to a vane, or piston and spring or the like. Excludes METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Alternate Parts: 1110 SIZE 2, F28211204, F282-1120-4, 1110 SIZE 2, 6680-01-312-0799, 01-312-0799, 6680013120799, 013120799

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66DEC 09, 198901-312-079938346 ( METER, FLOW RATE INDICATING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-312-0799
Part Number Cage Code Manufacturer
1110 SIZE 24ZW64BROOKS INSTRUMENT LLC
F282-1120-404577CARLETON TECHNOLOGIES INC
1110 SIZE 291556EMERSON ELECTRIC CODBA BROOKS INSTRUMENT DIVISION
Technical Data | NSN 6680-01-312-0799
Characteristic Specifications
DESIGN TYPEF$DAZN
SCALE QUANTITY1
DIAL SCALE MARKING RANGEP35.0/P350.0
DIAL SCALE REFERENCE POINTER NOT INCLUDED
METER TYPE FLOAT
OVERALL LENGTH15.120 INCHES NOMINAL
INTEGRAL PULSATION DAMPENER NOT INCLUDED
INLET CONNECTION TYPEG$F
INLET CONNECTION POSITION FOR WHICH DESIGNED HORIZONTAL
OUTLET CONNECTION TYPEG$F
OUTLET CONNECTION POSITION FOR WHICH DESIGNED HORIZONTAL
INTEGRAL RELIEF VALVE NOT INCLUDED
INTEGRAL HEAT SOURCE NOT INCLUDED
ALARM SIGNAL NOT INCLUDED
CONSTRUCTIONHN ANY ACCEPTABLE
BASE NOT INCLUDED
CARRYING HANDLE NOT INCLUDED
FLOAT QUANTITY1
FLOAT MATERIAL GLASS
SPINNING FLOAT NOT INCLUDED
FLOAT TYPE FREE
UNIT TYPE MOUNTED
MOUNTING METHOD SURFACE PANEL
INLET CONNECTION DEVICE TYPE STATIONARY
OUTLET CONNECTION DEVICE TYPE STATIONARY
SPECIAL FEATURESMODEL 1110,SIZE 2 ROTAMETER WITHBRACKETS FOR FLUSH PANEL MOUNTING BRASS FITTINGS,MILLED WINDOW SHIELD FOR PANEL MOUNTING,1/4 NPT;TUBE NO /2/25/DGLASS BALL FLOAT,TEN INCHS DETACHABLE DIRECT READING SCALE;SCC/M OXYGENAT70 DEGREES F& 29.92 "HG;ACCURACY PLUS OR O MINUS 2 PCT.;TUBE IS A STANDAED RIBBED GLASS TUBE;NOTLOGARITHMIC