NSN 6680-01-367-9721
Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-01-367-9721 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 17A8290X102, 6680-01-367-9721, 01-367-9721, 6680013679721, 013679721
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | NOV 22, 1992 | 01-367-9721 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-367-9721
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 17A8290X102 | 22508 | FISHER CONTROLS CO INC |
Technical Data | NSN 6680-01-367-9721
| Characteristic | Specifications |
|---|---|
| MEDIA FOR WHICH DESIGNED | WATER |
| PRESSURE TYPE | K$J |
| CASE MATERIAL | STEEL, STAINLESS |
| END ITEM IDENTIFICATION | 3655-00-722-3901; 4190 CONTROLLER |