NSN 6680-01-383-4754
Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-01-383-4754 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 10A1250, 6680-01-383-4754, 01-383-4754, 6680013834754, 013834754
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | NOV 24, 1993 | 01-383-4754 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-383-4754
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 10A1250 | 22809 | FISCHER AND PORTER CO WARMINSTERFIBERGLASS CO DIV |
Technical Data | NSN 6680-01-383-4754
| Characteristic | Specifications |
|---|---|
| MEDIA FOR WHICH DESIGNED | WATER |
| PRESSURE TYPE | LOW |
| MAXIMUM DIFFERENTIAL PRESSURE | FROM 0.1 TO 5GPM WATER |
| TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
| CASE SHAPE | RECTANGULAR |
| MOUNTING TYPE | ANY ACCEPTABLE |
| LENGTH | 3.000 INCHES NOMINAL |