NSN 6680-01-501-7107
Part Details | TRANSDUCER,WATER
6680-01-501-7107
Alternate Parts: 3183059331, 31830-5933-1, 6680-01-501-7107, 01-501-7107, 6680015017107, 015017107
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-501-7107
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 31830-5933-1 | 71871 | ALFA LAVAL INC. |
Technical Data | NSN 6680-01-501-7107
| Characteristic | Specifications |
|---|---|
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | MEDIA: MINERAL OIL; MEDIA TEMPERATURE: MAX. 110 DEGREES C; OPERATING PRESSURE: MAX. 600 KPA (6 BAR); TESTING PRESSURE: MAX. 1000 KPA (10 BAR); ENCLOSURE: 1P 65; CABLE CONNECTION: PR 22, 5/PG 13, 5 FOR CABLE PHASE 12, 5-15, 0; AMBIENT TEMPERATURE, CONNECTION BOX: MAX. 70 DEGREES C; FLANGE STANDARD: ACC. TO DIN 2633 AND JIS B2213; MATERIAL, BODY: PRESSURE VESSEL STEEL; ELECTRODE: STAINLESS STEEL; O-RINGS: VITON; INSULATORS: PTFE; CONNECTION BOX: ALUMINUM; WEIGHT: 7 KG; DIMENSIONS: SEE DIMENSION DRAWING; MOUNT STYLE: SEE DIMENSION DRAWING |
| SPECIAL FEATURES | THE FOPX SEPARATOR HAS NO GRAVITY DISCS; CONTINUOUS ELECTRONIC MONITORING OF WATER CONTENT IN THE LEANED OIL BY THE WATER TRANSDUCER WT 200 AND EPC-400 CONTROL UNIT; ALL LIMITS POINTS IN THE SYSTEM ARE SET IN THE EPC CONTROL UNIT; NO ADJUSTMENT OF THE SEPARATOR OR INDIVIDUALSENSORS ARE NEEDED; VIRTUALLY NO OIL LOSSES; CONTROLLED SUPPLY OF DISPLACEMENT WATER; SEPARATOR ADAPTED FOR THE ALFA LAVAL CIP SYSTEM |