NSN 6680-01-521-0396

Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER

6680-01-521-0396 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Alternate Parts: H034X341.55T1MF1SSSY100SP, H03/4X3/4-1.5-5-T-1MF1SS-SY100SP, SKECP5CG55, SK-ECP5-CG55, SKECP5CG55 ITEM 12, SK-ECP5-CG55 ITEM 12, 6680-01-521-0396, 01-521-0396, 6680015210396, 015210396

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JUN 08, 200401-521-039608249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-521-0396
Part Number Cage Code Manufacturer
H03/4X3/4-1.5-5-T-1MF1SS-SY100SP33321HOFFER FLOW CONTROLS, INC.
SK-ECP5-CG5505HX0NAVAL SURFACE WARFARE CENTERPHILADELPHIA DETACHMENT
SK-ECP5-CG55 ITEM 1205HX0NAVAL SURFACE WARFARE CENTERPHILADELPHIA DETACHMENT
Technical Data | NSN 6680-01-521-0396
Characteristic Specifications
SPECIAL FEATURESSP EQUALS 40 DEGREE BLADE ANGLE WHICH WILL CALIBRATE DOWN TO 1.5 GALLONS PER MINUTE, IDENTICAL TO PREVIOUSLY PURCHASED ITEM SERIAL NUMBER 101661