NSN 5920-00-356-2196
Part Details | PLUG FUSE
5920-00-356-2196 A fuse which mounts by means of a screw base.
Alternate Parts: 7025, T212, T2-1-2, T2 12, T2 1-2, WF791, 5920-00-356-2196, 00-356-2196, 5920003562196, 003562196
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-356-2196 | 00388 ( FUSE, PLUG ) |
REFERENCE DRAWINGS & PICTURES
EDISON BASE

Cross Reference | NSN 5920-00-356-2196
Part Number | Cage Code | Manufacturer |
---|---|---|
7025 | 71400 | COOPER BUSSMANN, LLCDBA COOPER BUSSMANN |
T2-1-2 | 71400 | COOPER BUSSMANN, LLCDBA COOPER BUSSMANN |
T2 1-2 | 71400 | COOPER BUSSMANN, LLCDBA COOPER BUSSMANN |
WF791 | 81348 | FEDERAL SPECIFICATIONSPROMULGATED BY GENERAL SERVICES |
Technical Data | NSN 5920-00-356-2196
Characteristic | Specifications |
---|---|
BODY STYLE | EDISON BASE |
OVERALL LENGTH | 1.281 INCHES NOMINAL |
OVERALL DIAMETER | 1.812 INCHES NOMINAL |
CONTINUOUS CURRENT RATING IN AMPS | 2.500 |
MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 DC |
CIRCUIT OVER-CURRENT INTERRUPTION TYPE | TIME DELAY |
CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS | 12.0 200 PCT OF CURRENT RATING |
INTERRUPTION INDICATOR METHOD | VISIBLE ELEMENT |
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS | 10000.0 |
SPECIAL FEATURES | W/THERMAL CUTOUT |
NONDEFINITIVE SPEC/STD DATA | 2 TYPE AND C STYLE AND 2 CLASS |
DEPARTURE FROM CITED DESIGNATOR | AS MODIFIED BY PAC FEAT |