NSN 5930-00-064-8015

Part Details | THERMOSTATIC SWITCH

5930-00-064-8015 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 22232NL12221409, 222-32NL1-2221409, 22232NL12221409, 222-32NL1-2221409, NF920142, NF9-20142, 5930-00-064-8015, 00-064-8015, 5930000648015, 000648015

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-064-801500451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-064-8015
Part Number Cage Code Manufacturer
222-32NL1-222140996452AMERICAN STANDARD INC CONTROLS DEPTPRODUCTS GROUP
222-32NL1-222140919278DETROIT SWITCH, INC.
NF9-2014288234UNITED ELECTRIC CONTROLS COMPANY
Technical Data | NSN 5930-00-064-8015
Characteristic Specifications
OVERALL LENGTH5.000 INCHES NOMINAL
OVERALL WIDTH2.688 INCHES NOMINAL
BODY HEIGHT2.750 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+150.00 TO +225.00 ACTUATION POINT DEGREES FAHRENHEIT AND +150.00 TO +225.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW
MEDIA FOR WHICH DESIGNEDQ$DADF
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE
CAPILLARY TUBE LENGTH120.0 INCHES NOMINAL
TERMINAL TYPE SCREW
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.656 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.281 INCHES NOMINAL
FEATURES PROVIDED ELECTRICAL ACCESS PORT