NSN 5930-00-068-9026
Part Details | PRESSURE SWITCH
5930-00-068-9026 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 6607244, 6607-2-44, 128SCP13713, 128SCP137-13, 5930-00-068-9026, 00-068-9026, 5930000689026, 000689026
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-068-9026 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-068-9026
Part Number | Cage Code | Manufacturer |
---|---|---|
6607-2-44 | 02750 | EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION |
128SCP137-13 | 26512 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS |
Technical Data | NSN 5930-00-068-9026
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 8 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 3.000 INCHES MAXIMUM |
BODY LENGTH | 2.130 INCHES NOMINAL |
OVERALL DIAMETER | 1.375 INCHES MAXIMUM |
PRESSURE SWITCH TYPE | DIFFERENTIAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | DECREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BD9.00 ACTUATION POINT MINIMUM AND BD11.50 ACTUATION POINT MAXIMUM AND BD0.50 DIFFERENTIAL POINT MINIMUM AND BD2.00 DIFFERENTIAL POINT MAXIMUM |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
PROOF PRESSURE | 75.00 POUNDS PER SQUARE INCH GAGE |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | CLAMP |
FEATURES PROVIDED | ELECTRICAL ACCESS PORT |