NSN 5930-00-072-4896

Part Details | THERMOSTATIC SWITCH

5930-00-072-4896 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 22210NN2221224, 222-10NN2221224, 1JH2801PIECE92, 5930-00-072-4896, 00-072-4896, 5930000724896, 000724896

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-072-489600451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR

Cross Reference | NSN 5930-00-072-4896
Part Number Cage Code Manufacturer
222-10NN222122419278DETROIT SWITCH, INC.
1JH2801PIECE9211660WESTINGHOUSE ELECTRIC CORPCONTROL BUSINESS UNIT
Technical Data | NSN 5930-00-072-4896
Characteristic Specifications
STYLE DESIGNATOR3 RECTANGULAR
OVERALL LENGTH5.375 INCHES NOMINAL
OVERALL HEIGHT3.625 INCHES NOMINAL
OVERALL WIDTH2.688 INCHES NOMINAL
BODY HEIGHT2.500 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+140.00 TO +215.00 ACTUATION POINT DEGREES FAHRENHEIT AND +128.00 TO +203.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW
OPERATING TEMP RATING-30.0 DEG FAHRENHEIT MINIMUM AND 245.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH120.0 INCHES NOMINAL
BULB LENGTH6.000 INCHES NOMINAL
BULB DIAMETER1.125 INCHES NOMINAL
TERMINAL TYPE SCREW
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.750 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.281 INCHES NOMINAL
FEATURES PROVIDED TUBING END SEAL CONNECTION
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION DUSTPROOF AND WATERTIGHT
PRECIOUS MATERIAL SILVER
PRECIOUS MATERIAL AND LOCATIONCONTACTS SILVER