NSN 5930-00-091-9254
Part Details | THERMOSTATIC SWITCH
5930-00-091-9254 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 2039741, 203974-1, 134SCEC12515, 134SCEC125-15, 21738, 5930-00-091-9254, 00-091-9254, 5930000919254, 000919254
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAY 22, 1968 | 00-091-9254 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-091-9254
Part Number | Cage Code | Manufacturer |
---|---|---|
203974-1 | 70210 | HONEYWELL INTERNATIONAL INC.DBA HONEYWELL |
134SCEC125-15 | 26512 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS |
21738 | 73803 | TEXAS INSTRUMENTS INCMETALLURGICAL MATERIALS DIV |
Technical Data | NSN 5930-00-091-9254
Characteristic | Specifications |
---|---|
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AF400.00 ACTUATION POINT NOMINAL |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
CAPILLARY TUBE LENGTH | 2.000 INCHES MINIMUM AND 2.300 INCHES MAXIMUM |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | BRACKET |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |