NSN 5930-00-096-2881
Part Details | THERMOSTATIC SWITCH
5930-00-096-2881 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: Z2427118, Z24271-18, Z2774018, Z27740-18, 5930-00-096-2881, 00-096-2881, 5930000962881, 000962881
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-096-2881 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR

Cross Reference | NSN 5930-00-096-2881
Part Number | Cage Code | Manufacturer |
---|---|---|
Z24271-18 | 80625 | ROBERTSHAW CONTROLS COEXECUTIVE OFFICE |
Z27740-18 | 77857 | ROBERTSHAW CONTROLS CONEW STANTON DIV |
Technical Data | NSN 5930-00-096-2881
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 2 RECTANGULAR |
OVERALL LENGTH | 3.062 INCHES NOMINAL |
OVERALL HEIGHT | 3.250 INCHES NOMINAL |
OVERALL WIDTH | 3.250 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | +230.00 TO +270.00 ACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB WITH SCALE |
CONTACT STIMULUS RATING | AF2.00 DIFFERENTIAL POINT NOMINAL |
OPERATING TEMP RATING | -273.1 DEG CELSIUS MINIMUM AND 345.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
CAPILLARY TUBE LENGTH | 18.000 INCHES NOMINAL |
BULB LENGTH | 11.000 INCHES NOMINAL |
BULB DIAMETER | 0.531 INCHES NOMINAL |
TERMINAL TYPE | TAB W/SCREW |
MOUNTING METHOD | BRACKET |
FEATURES PROVIDED | TUBING END SEAL CONNECTION |
SPECIAL FEATURES | SUPPLIED WITH OVER-RUN CONTACTS WHICH OPERATE AT 50 DEG F ALONGANY DIAL SETTING AND MUST BE MANUALLY RESET |