NSN 5930-00-099-0556

Part Details | THERMOSTATIC SWITCH

5930-00-099-0556 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 2221305, 22210NL2221305, 222-10NL2221305, 22210ANL2221305, 222-10ANL-2221305, 5930-00-099-0556, 00-099-0556, 5930000990556, 000990556

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59DEC 13, 197200-099-055600451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR

Cross Reference | NSN 5930-00-099-0556
Part Number Cage Code Manufacturer
222130519278DETROIT SWITCH, INC.
222-10NL222130519278DETROIT SWITCH, INC.
222-10ANL-222130519278DETROIT SWITCH, INC.
Technical Data | NSN 5930-00-099-0556
Characteristic Specifications
STYLE DESIGNATOR2 RECTANGULAR
OVERALL LENGTH4.875 INCHES NOMINAL
OVERALL HEIGHT5.687 INCHES NOMINAL
OVERALL WIDTH2.875 INCHES NOMINAL
BODY LENGTH4.625 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+70.00 TO +140.00 ACTUATION POINT DEGREES FAHRENHEIT AND +67.00 TO +137.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL ACTUATION POINT SCREW
OPERATING TEMP RATING167.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED LIQUID
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH120.0 INCHES NOMINAL
BULB LENGTH3.625 INCHES NOMINAL
BULB DIAMETER0.688 INCHES NOMINAL
TERMINAL TYPE TAB W/SCREW
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.750 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS2.500 INCHES NOMINAL
FEATURES PROVIDED ELECTRICAL ACCESS PORT
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION WATERTIGHT AND DUSTPROOF
PRECIOUS MATERIAL SILVER
PRECIOUS MATERIAL AND LOCATIONCONTACTS SILVER