Part Details | PRESSURE SWITCH
5930-00-111-1861 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: M93950301, M9395/03-01, MILS93953, MILS9395-3, 5930-00-111-1861, 00-111-1861, 5930001111861, 001111861
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | AUG 23, 1968 | 00-111-1861 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL

Cross Reference | NSN 5930-00-111-1861
Part Number | Cage Code | Manufacturer |
---|---|---|
M9395/03-01 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MILS9395-3 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-00-111-1861
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 6 CYLINDRICAL |
OVERALL LENGTH | 3.750 INCHES MAXIMUM |
OVERALL WIDTH | 3.540 INCHES NOMINAL |
BODY DIAMETER | 3.000 INCHES NOMINAL |
PRESSURE SWITCH TYPE | ABSOLUTE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BC14.50 ACTUATION POINT NOMINAL AND BC12.00 DEACTUATION POINT NOMINAL AND BC2.50 DIFFERENTIAL POINT NOMINAL |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
PROOF PRESSURE | 120.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.217 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.030 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.000 INCHES NOMINAL |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
TEST DATA DOCUMENT | 81349-MIL-S-9395 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL--9395 TO 3 GOVERNMENT SPECIFICATION |
SENSING ELEMENT BURST PRESSURE | 180.00 POUNDS PER SQUARE INCH |