NSN 5930-00-133-5331
Part Details | PRESSURE SWITCH
5930-00-133-5331 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 5930001335331, 7091, 707012, 11072966, 5930-00-133-5331, 00-133-5331, 5930001335331, 001335331
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | DEC 26, 1968 | 00-133-5331 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL

Cross Reference | NSN 5930-00-133-5331
Part Number | Cage Code | Manufacturer |
---|---|---|
5930001335331 | A00AM | E.C.A ETABLISSEMENT CENTRALDESAPPROVISIONNEMENTS DES FORCES |
7091 | 98505 | HYDRA-ELECTRIC COMPANY |
707012 | 24038 | SIGMA-NETICS, INC. |
11072966 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
Technical Data | NSN 5930-00-133-5331
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 1 CYLINDRICAL |
OVERALL LENGTH | 3.000 INCHES MAXIMUM |
WIDTH ACROSS FLATS | 1.000 INCHES MAXIMUM |
BODY LENGTH | 2.375 INCHES NOMINAL |
OVERALL DIAMETER | 1.250 INCHES NOMINAL |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BD30.00 ACTUATION POINT NOMINAL AND BD5.00 DEACTUATION POINT NOMINAL |
OPERATING TEMP RATING | 40.0 DEG FAHRENHEIT MINIMUM AND 130.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS, LIQUEFIED |
TERMINAL TYPE | WIRE LEAD |
MOUNTING METHOD | LINE |