NSN 5930-00-185-5142
Part Details | ROTARY SWITCH
5930-00-185-5142 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).
Alternate Parts: 36301102, 3630-110-2, 338111847, 33-811184-7, 1905M210N, 1905M2-10N, M378640031, M3786/4-0031, MILS37864, MILS3786-4, MILDTL37864, MIL-DTL-3786/4, 41863360, 418633-60, 5930-00-185-5142, 00-185-5142, 5930001855142, 001855142
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | FEB 19, 1971 | 00-185-5142 | 02134 ( SWITCH, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
TAP, CIRCULAR, BUSHING MOUNT

Cross Reference | NSN 5930-00-185-5142
Part Number | Cage Code | Manufacturer |
---|---|---|
3630-110-2 | 31946 | COLE INSTRUMENT CORP. |
33-811184-7 | 07397 | GENERAL DYNAMICS ADVANCEDINFORMATION SYSTEMS INC. |
1905M2-10N | 91812 | JANCO CORPORATIONDBA ESTERLINE MASON |
M3786/4-0031 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MILS3786-4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-DTL-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
418633-60 | 96214 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5930-00-185-5142
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
OVERALL LENGTH | 2.112 INCHES MINIMUM AND 2.378 INCHES MAXIMUM |
OVERALL DIAMETER | 1.100 INCHES MINIMUM AND 1.306 INCHES MAXIMUM |
INDIVIDUAL SECTION QUANTITY | 2 |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
TERMINAL TYPE | TAB, SOLDER LUG |
TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
OPERATING TEMP RANGE | -65.0 TO +85.0 DEG CELSIUS |