NSN 5930-00-233-2730

Part Details | ROTARY SWITCH

5930-00-233-2730 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).

Alternate Parts: 26039475, 2603947-5, SC593000154, SC5930-0015-4, 338111845, 33-811184-5, 44M300317N, 44M30-03-1-7N, 1905M37N, 1905M3-7N, M378640050, M3786/4-0050, M3786040050, M3786/04-0050, MILS37864, MILS3786-4, MILDTL37864, MIL-DTL-3786/4, 37662296004, 37662296-004, 5930-00-233-2730, 00-233-2730, 5930002332730, 002332730

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59NOV 04, 197000-233-273002134 ( SWITCH, ROTARY )
REFERENCE DRAWINGS & PICTURES

TAP, CIRCULAR, BUSHING MOUNT

Cross Reference | NSN 5930-00-233-2730
Part Number Cage Code Manufacturer
2603947-506424ALLIANT TECHSYSTEMS OPERATIONS LLCDIV DEFENSE ELECTRONIC SYSTEMS
SC5930-0015-412115DRS ICAS, LLC
33-811184-507397GENERAL DYNAMICS ADVANCEDINFORMATION SYSTEMS INC.
44M30-03-1-7N81073GRAYHILL, INC
1905M3-7N91812JANCO CORPORATIONDBA ESTERLINE MASON
M3786/4-005081349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
M3786/04-005081349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MILS3786-481349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-DTL-3786/481349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
37662296-00408783RAYTHEON CO
Technical Data | NSN 5930-00-233-2730
Characteristic Specifications
STYLE DESIGNATOR TAP, CIRCULAR, BUSHING MOUNT
OVERALL LENGTH2.427 INCHES MINIMUM AND 2.755 INCHES MAXIMUM
OVERALL DIAMETER1.100 INCHES MINIMUM AND 1.306 INCHES MAXIMUM
INDIVIDUAL SECTION QUANTITY3
SWITCH CONTACT BASIC DESIGN NONPILE-UP SYMMETRICAL
TERMINAL TYPE TAB, SOLDER LUG
TEST DATA DOCUMENT81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION EXPLOSION PROOF
OPERATING TEMP RANGE-65.0 TO +85.0 DEG CELSIUS