NSN 5930-00-270-1227
Part Details | ROTARY SWITCH
5930-00-270-1227 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).
Alternate Parts: 42M360818N, 42M36-08-1-8N, 4M36EB18N8, 4M36EB1-8N8, M378640434, M3786/4-0434, MILS37864, MIL-S-3786/4, MILDTL37864, MIL-DTL-3786/4, 5930-00-270-1227, 00-270-1227, 5930002701227, 002701227
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | AUG 26, 1973 | 00-270-1227 | 02134 ( SWITCH, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
TAP, CIRCULAR, BUSHING MOUNT

Cross Reference | NSN 5930-00-270-1227
Part Number | Cage Code | Manufacturer |
---|---|---|
42M36-08-1-8N | 81073 | GRAYHILL, INC |
4M36EB1-8N8 | 91812 | JANCO CORPORATIONDBA ESTERLINE MASON |
M3786/4-0434 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-S-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-DTL-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-00-270-1227
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
OVERALL LENGTH | 4.321 INCHES NOMINAL |
OVERALL DIAMETER | 1.000 INCHES MINIMUM AND 1.306 INCHES MAXIMUM |
INDIVIDUAL SECTION QUANTITY | 8 |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
TERMINAL TYPE | TAB, SOLDER LUG |
SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL--3786 TO 4 GOVERNMENT SPECIFICATION |
CRITICALITY CODE JUSTIFICATION | FEAT |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
OPERATING TEMP RANGE | -65.0 TO +85.0 DEG CELSIUS |