5930-00-329-6497 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 7015921, 70-1592-1, 50221197, 5022-11-97, 5930-00-329-6497, 00-329-6497, 5930003296497, 003296497

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59DEC 09, 197300-329-649700451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-329-6497
Part Number Cage Code Manufacturer
70-1592-130554DEPARTMENT OF DEFENSE PROJECTMANAGER-MOBILE ELECTRIC POWER
5022-11-9728340PROTECTIVE CONTROLS INC
Technical Data | NSN 5930-00-329-6497
Characteristic Specifications
STYLE DESIGNATOR3 CYLINDRICAL W/FLANGE
OVERALL LENGTH2.850 INCHES MINIMUM AND 2.910 INCHES MAXIMUM
WIDTH ACROSS FLATS0.850 INCHES MINIMUM AND 0.910 INCHES MAXIMUM
BODY DIAMETER0.540 INCHES MINIMUM AND 0.550 INCHES MAXIMUM
BODY LENGTH1.750 INCHES MINIMUM AND 1.810 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION, WITH CONTACT ON ARM.
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAF150.00 ACTUATION POINT NOMINAL AND AF130.00 DEACTUATION POINT NOMINAL
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 600.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE BULB
CAPILLARY TUBE LENGTH0.970 INCHES MINIMUM AND 1.030 INCHES MAXIMUM
TERMINAL TYPE TAB W/SCREW
MOUNTING METHOD THREADED BUSHING
FEATURES PROVIDED HERMETICALLY SEALED CASE