NSN 5930-00-359-4219

Part Details | THERMOSTATIC SWITCH

5930-00-359-4219 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 060003284, 060-003284, 060003278, 060-003278, 3BTL3153, 3BTL3-153, 5930-00-359-4219, 00-359-4219, 5930003594219, 003594219

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59FEB 18, 197400-359-421900451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-359-4219
Part Number Cage Code Manufacturer
060-00328426916NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MULTIPLE
060-00327826916NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MULTIPLE
3BTL3-15382647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
Technical Data | NSN 5930-00-359-4219
Characteristic Specifications
STYLE DESIGNATOR CYLINDRICAL W/FLANGE
OVERALL LENGTH0.343 INCHES MINIMUM AND 0.403 INCHES MAXIMUM
WIDTH ACROSS FLATS0.281 INCHES NOMINAL
BODY LENGTH0.160 INCHES MINIMUM AND 0.180 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAF360.00 ACTUATION POINT NOMINAL AND AF330.00 DEACTUATION POINT NOMINAL
OPERATING TEMP RATING-80.0 DEG FAHRENHEIT MINIMUM AND 400.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD THREADED BUSHING
FEATURES PROVIDED INTERNALLY GROUNDED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION WEATHERPROOF