NSN 5930-00-387-2668
Part Details | THERMOSTATIC SWITCH
5930-00-387-2668 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: B59234, B5923-4, 3ART5AE7, 9530N463, 72B59234R1, 72-B5923-4R1, 5930-00-387-2668, 00-387-2668, 5930003872668, 003872668
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAR 21, 1974 | 00-387-2668 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR

Cross Reference | NSN 5930-00-387-2668
Part Number | Cage Code | Manufacturer |
---|---|---|
B5923-4 | 96325 | AMANA REFRIGERATION INCSUB OF RAYTHEON CO |
3ART5AE7 | 03513 | GENERAL ELECTRIC COAPPLIANCE CONTROL DEPT |
9530N463 | 81640 | SAFRAN ELECTRICAL & POWER USA, LLCDBA LABINAL POWER SYSYEMS |
72-B5923-4R1 | 81640 | SAFRAN ELECTRICAL & POWER USA, LLCDBA LABINAL POWER SYSYEMS |
Technical Data | NSN 5930-00-387-2668
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | RECTANGULAR |
OVERALL LENGTH | 3.360 INCHES NOMINAL |
OVERALL HEIGHT | 2.088 INCHES NOMINAL |
OVERALL WIDTH | 1.470 INCHES NOMINAL |
BODY LENGTH | 1.500 INCHES NOMINAL |
BODY WIDTH | 1.000 INCHES NOMINAL |
BODY HEIGHT | 1.375 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | +4.00 TO +10.30 ACTUATION POINT DEGREES FAHRENHEIT AND -15.00 TO -9.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SHAFT AND EXTERNAL ACTUATION POINT SHAFT |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
CAPILLARY TUBE LENGTH | 12.250 INCHES NOMINAL |
TERMINAL TYPE | QUICK DISCONNECT, MALE |
MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.000 INCHES NOMINAL |