NSN 5930-00-477-7772
Part Details | ROTARY SWITCH
5930-00-477-7772 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).
Alternate Parts: 71C815002, 71C815-002, 80024, 8002-4, 8M360214N, 8M36-02-1-4N, 8A360214N, 8A36-02-1-4N, 08A3602104N, 08A36-02-1-04N, M3786130453, M3786/13-0453, MILS378613, MIL-S-3786/13, 5930-00-477-7772, 00-477-7772, 5930004777772, 004777772
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JUN 12, 1974 | 00-477-7772 | 02134 ( SWITCH, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
TAP, CIRCULAR, BUSHING MOUNT

Cross Reference | NSN 5930-00-477-7772
Part Number | Cage Code | Manufacturer |
---|---|---|
71C815-002 | 04660 | AIL SYSTEMS INCSUB OF EATON CORP |
8002-4 | 81073 | GRAYHILL, INC |
8M36-02-1-4N | 81073 | GRAYHILL, INC |
8A36-02-1-4N | 81073 | GRAYHILL, INC |
08A36-02-1-04N | 81073 | GRAYHILL, INC |
M3786/13-0453 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-S-3786/13 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-00-477-7772
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
OVERALL LENGTH | 1.965 INCHES NOMINAL |
OVERALL DIAMETER | 0.670 INCHES MINIMUM AND 0.800 INCHES MAXIMUM |
INDIVIDUAL SECTION QUANTITY | 2 |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
TERMINAL TYPE | TAB, SOLDER LUG |
TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL--3786 TO 13 GOVERNMENT SPECIFICATION |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
OPERATING TEMP RANGE | -65.0 TO +85.0 DEG CELSIUS |