NSN 5930-00-521-5449

Part Details | THERMOSTATIC SWITCH

5930-00-521-5449 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 2543200, 6954793, 695479-3, G954793, G95479-3, 501002, 5-01002, 25523164, 5930-00-521-5449, 00-521-5449, 5930005215449, 005215449

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-521-544900451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-521-5449
Part Number Cage Code Manufacturer
254320099167HAMILTON SUNDSTRAND CORPORATION
695479-398897LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN AERONAUTICS
G95479-398897LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN AERONAUTICS
5-0100218509PSG CONTROLS, INC.
2552316480234VAPOR CORPSUB OF BRUNSWICK CORP
Technical Data | NSN 5930-00-521-5449
Characteristic Specifications
STYLE DESIGNATOR1 CYLINDRICAL W/FLANGE
OVERALL LENGTH4.560 INCHES MINIMUM AND 4.680 INCHES MAXIMUM
BODY DIAMETER0.460 INCHES MINIMUM AND 0.520 INCHES MAXIMUM
BODY LENGTH2.820 INCHES MINIMUM AND 2.940 INCHES MAXIMUM
OVERALL DIAMETER1.570 INCHES MINIMUM AND 1.630 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAF135.00 ACTUATION POINT MINIMUM AND AF145.00 ACTUATION POINT MAXIMUM AND AF120.00 DEACTUATION POINT NOMINAL
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNEDQ$DADF
TEMP SENSING ELEMENT TYPE BULB
TERMINAL TYPE CONNECTOR, RECEPTACLE
MOUNTING METHOD UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.166 INCHES MINIMUM AND 0.177 INCHES MAXIMUM
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.245 INCHES MINIMUM AND 1.255 INCHES MAXIMUM
SPECIAL FEATURESRECEPTACLE TO HAVE PROVISIONS FOR LOCKWIRING PLUG