NSN 5930-00-531-0541
Part Details | LIQUID LEVEL SWITCH
5930-00-531-0541 A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY.
Alternate Parts: F2071, F207-1, 322722P1, 322722, 322722P1, 322722, 5930-00-531-0541, 00-531-0541, 5930005310541, 005310541
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | SEP 11, 1974 | 00-531-0541 | 37187 ( SWITCH, LIQUID LEVEL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-531-0541
Part Number | Cage Code | Manufacturer |
---|---|---|
F207-1 | 53655 | AVOX SYSTEMS INC. |
322722P1 | 33654 | HOWDEN FLUID SYSTEMS |
322722 | 33654 | HOWDEN FLUID SYSTEMS |
322722P1 | 58163 | MEGGITT (NORTH HOLLYWOOD), INC.DBA MEGGITT CONTROL SYSTEMS |
322722 | 58163 | MEGGITT (NORTH HOLLYWOOD), INC.DBA MEGGITT CONTROL SYSTEMS |
Technical Data | NSN 5930-00-531-0541
Characteristic | Specifications |
---|---|
DC VOLTAGE RATING | A28.0 VOLTS |
INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES NOMINAL LOAD |
ELECTRICAL CONNECTION TYPE | CONNECTOR PLUG |
CONNECTOR MANUFACTURER CODE | 06845 |
CONNECTOR IDENTIFICATION | PT02E-8-3P |
RELAY | NOT INCLUDED |
LIQUID TYPE FOR WHICH DESIGNED | HYDRAULIC FLUID |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT NOMINAL AND 250.0 DEG FAHRENHEIT NOMINAL |
ACTUATION METHOD | BUOYANCY |
FLOAT QUANTITY | 1 |
FLOAT EFFECTIVE TRAVEL | 0.500 INCHES NOMINAL |
MOUNTING POSITION | HORIZONTAL |
MOUNTING METHOD | FLANGE |
MOUNTING DIMENSIONS | FOUR 0.205IN. DIA NOM MTG HOLES EQUALLY SPACED ON 2.120 IN. BOLT CIRCLE DIA |
OVERALL DIAMETER | 2.620 INCHES NOMINAL |
TANK INSERTION LENGTH | 6.000 INCHES MAXIMUM |
SPECIFIC EQUIPMENT ACCOMMODATED | HYDRAULIC SYSTEM HS527 |