NSN 5930-00-613-2631
Part Details | LIQUID LEVEL SWITCH
5930-00-613-2631 A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY.
Alternate Parts: 36969, 369-69, 369, 5006007, 500-6007, VB48, VB4-8, 69, M0DEL 69, 5930-00-613-2631, 00-613-2631, 5930006132631, 006132631
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-613-2631 | 37187 ( SWITCH, LIQUID LEVEL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-613-2631
Part Number | Cage Code | Manufacturer |
---|---|---|
369-69 | 07657 | BLICKMAN CASEWORK AND DESIGN CORP |
369 | 07657 | BLICKMAN CASEWORK AND DESIGN CORP |
500-6007 | 52151 | CONTINENTAL ELECTRONICS CORPORATION |
VB4-8 | 98437 | ELLIS & WATTS INTERNATIONAL, LLC |
69 | 39305 | ITT MCDONNELL-MILLER A UNIT OF ITTFLUID HANDLING DIV |
M0DEL 69 | 39305 | ITT MCDONNELL-MILLER A UNIT OF ITTFLUID HANDLING DIV |
Technical Data | NSN 5930-00-613-2631
Characteristic | Specifications |
---|---|
CURRENT RATING AT MAXIMUM RATED VOLTAGE | 7.4 AMPERES NOMINAL LOAD |
CONTACT ARRANGEMENT | 2 CIRCUIT,DOUBLE BREAK |
ELECTRICAL CONNECTION TYPE | CABLE |
RELAY | NOT INCLUDED |
LIQUID TYPE FOR WHICH DESIGNED | WATER |
OPERATING TEMP RATING | 300.0 DEG FAHRENHEIT MAXIMUM |
ACTUATION METHOD | BUOYANCY |
FLOAT QUANTITY | 1 |
FLOAT EFFECTIVE TRAVEL | 0.750 INCHES NOMINAL |
MOUNTING POSITION | HORIZONTAL |
MOUNTING METHOD | THREAD |
MOUNTING DIMENSIONS | MTG BY 2-1/2 IN. -8 NPT THD CONNECTION |
OVERALL LENGTH | 9.500 INCHES NOMINAL |
OVERALL DIAMETER | 4.063 INCHES NOMINAL |
TANK INSERTION LENGTH | 4.125 INCHES MAXIMUM |