NSN 5930-00-621-9986

Part Details | ROTARY SWITCH

5930-00-621-9986 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).

Alternate Parts: 3961663, 396166-3, 53SM1503124N, 53SM15-03-1-24N, 53M1503124N, 53M15-03-1-24N, 53MS1503124NC, 53MS15-03-1-24NC, 53HS1503124N, 53HS15-03-1-24N, M3786360128, M3786/36-0128, MILS378636, MIL-S-3786/36, 3370032003, 3370032-003, 5930-00-621-9986, 00-621-9986, 5930006219986, 006219986

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59FEB 27, 197500-621-998602134 ( SWITCH, ROTARY )
REFERENCE DRAWINGS & PICTURES

TAP, CIRCULAR, BUSHING MOUNT

Cross Reference | NSN 5930-00-621-9986
Part Number Cage Code Manufacturer
396166-300752EDO LLCDIV ANTENNA PRODUCTS
53SM15-03-1-24N81073GRAYHILL, INC
53M15-03-1-24N81073GRAYHILL, INC
53MS15-03-1-24NC81073GRAYHILL, INC
53HS15-03-1-24N81073GRAYHILL, INC
M3786/36-012881349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-S-3786/3681349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
3370032-00392755NORTHROP GRUMMAN SYSTEMS CORPORATIONDBA LAND & SELF PROTECTION SYSTEM
Technical Data | NSN 5930-00-621-9986
Characteristic Specifications
STYLE DESIGNATOR TAP, CIRCULAR, BUSHING MOUNT
OVERALL LENGTH2.488 INCHES NOMINAL
OVERALL DIAMETER1.350 INCHES NOMINAL
INDIVIDUAL SECTION QUANTITY3
SWITCH CONTACT BASIC DESIGN NONPILE-UP SYMMETRICAL
TERMINAL TYPE TAB, SOLDER LUG
TEST DATA DOCUMENT81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL--3786 TO 36 GOVERNMENT SPECIFICATION
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION EXPLOSION PROOF
OPERATING TEMP RANGE-65.0 TO +125.0 DEG CELSIUS