NSN 5930-00-702-7115
Part Details | PRESSURE SWITCH
5930-00-702-7115 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 421E10L, 1406566PC1, 1406566PC1, 1639175PC1, 5930-00-702-7115, 00-702-7115, 5930007027115, 007027115
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-702-7115 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL

Cross Reference | NSN 5930-00-702-7115
Part Number | Cage Code | Manufacturer |
---|---|---|
421E10L | 89326 | BARKSDALE INC |
1406566PC1 | 06840 | BENDIX CORP THE |
1406566PC1 | 03023 | HONEYWELL INTL INCDEFENSE AVIONICS SYSTEMS |
1639175PC1 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
Technical Data | NSN 5930-00-702-7115
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 6 CYLINDRICAL |
OVERALL LENGTH | 4.125 INCHES MAXIMUM |
OVERALL WIDTH | 3.625 INCHES MAXIMUM |
BODY DIAMETER | 3.000 INCHES NOMINAL |
BODY LENGTH | 2.312 INCHES NOMINAL |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CONTACT ADJUSTMENT RANGE | +0.40 TO +30.00 ACTUATION POINT INCHES OF MERCURY AND +0.40 TO +30.00 DEACTUATION POINT INCHES OF MERCURY |
CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
CONTACT STIMULUS RATING | AQ0.50 ACTUATION POINT MINIMUM AND AQ31.40 ACTUATION POINT MAXIMUM AND AQ0.10 DIFFERENTIAL POINT MINIMUM AND AQ1.40 DIFFERENTIAL POINT MAXIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
PROOF PRESSURE | 30.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | WIRE LEAD |
MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.203 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.000 INCHES NOMINAL |