NSN 5930-00-842-0177
Part Details | THERMOSTATIC SWITCH
5930-00-842-0177 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: TA103A, TA103, 876M0DEL5000, 826XHM0D2000, 1766, 176-6, T26T3, T26T-3, TYPE874A01M0D1002, T26T3, T26T-3, 5530060004, 55-30060-004, 5930-00-842-0177, 00-842-0177, 5930008420177, 008420177
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1962 | 00-842-0177 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-842-0177
Part Number | Cage Code | Manufacturer |
---|---|---|
TA103A | 05624 | GE AVIATION SYSTEMS LLCDBA GE AVIATION |
TA103 | 05624 | GE AVIATION SYSTEMS LLCDBA GE AVIATION |
876M0DEL5000 | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
826XHM0D2000 | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
176-6 | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
T26T-3 | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
TYPE874A01M0D1002 | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
T26T-3 | 32242 | JOHNSON CONTROLS, INC.DBA JOHNSON CONTROLS |
55-30060-004 | 81616 | YORK INDUSTRIES, INC. |
Technical Data | NSN 5930-00-842-0177
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 4.000 INCHES NOMINAL |
OVERALL HEIGHT | 1.500 INCHES NOMINAL |
OVERALL WIDTH | 2.063 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | +40.00 TO +90.00 ACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB W/SCREW |
MOUNTING METHOD | FLANGE |
FEATURES PROVIDED | VISUAL INDICATING THERMOMETER |