NSN 5930-00-902-5066

Part Details | THERMOSTATIC SWITCH

5930-00-902-5066 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: B559339, B5-59-339, 471557, 471-557, 5930-00-902-5066, 00-902-5066, 5930009025066, 009025066

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAY 04, 196600-902-506600451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-902-5066
Part Number Cage Code Manufacturer
B5-59-33981361EDGEWOOD CHEMICAL BIOLOGICAL CENTERECBC
471-55793410ESSEX GROUP INC CONTROLS DIVLEXINGTON PLANT
Technical Data | NSN 5930-00-902-5066
Characteristic Specifications
STYLE DESIGNATOR8 CYLINDRICAL W/FLANGE
OVERALL LENGTH3.670 INCHES NOMINAL
BODY LENGTH0.550 INCHES NOMINAL
OVERALL DIAMETER0.690 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE+200.00 TO +600.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT DIAL
CONTACT STIMULUS RATINGAF300.00 DIFFERENTIAL POINT NOMINAL
MEDIA FOR WHICH DESIGNEDQ$DADF
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE
CAPILLARY TUBE LENGTH2.750 INCHES NOMINAL
TERMINAL TYPE PIN
MOUNTING METHOD THREADED BUSHING
FEATURES PROVIDED TUBING END SEAL CONNECTION
SPECIAL FEATURESWEAPON SYSTEN ESSENTIAL
CRITICALITY CODE JUSTIFICATIONFEAT