NSN 5930-00-910-5844

Part Details | THERMOSTATIC SWITCH

5930-00-910-5844 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 3318287, 3318-287, 312331827800, 312-3318278-00, 32411040 MOD3, 32411-0-40 MOD3, 5930-00-910-5844, 00-910-5844, 5930009105844, 009105844

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196000-910-584400451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR

Cross Reference | NSN 5930-00-910-5844
Part Number Cage Code Manufacturer
3318-28790073CMC ELECTRONICS INC
312-3318278-0090073CMC ELECTRONICS INC
32411-0-40 MOD315801HONEYWELL INTERNATIONAL INC.DBA HONEYWELL
Technical Data | NSN 5930-00-910-5844
Characteristic Specifications
STYLE DESIGNATOR RECTANGULAR
OVERALL LENGTH1.250 INCHES NOMINAL
OVERALL HEIGHT0.440 INCHES MAXIMUM
OVERALL WIDTH0.401 INCHES NOMINAL
BODY LENGTH0.776 INCHES NOMINAL
BODY WIDTH0.401 INCHES NOMINAL
BODY HEIGHT0.251 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE+35.00 TO +45.00 ACTUATION POINT DEGREES FAHRENHEIT AND +35.00 TO +45.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW
CONTACT STIMULUS RATINGAF40.00 ACTUATION POINT NOMINAL AND AF0.00 DEACTUATION POINT NOMINAL
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 200.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNEDQ$DADF
TEMP SENSING ELEMENT TYPE IMMERSION WELL
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.156 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.000 INCHES NOMINAL
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.000 INCHES NOMINAL