NSN 5930-01-026-6361

Part Details | PRESSURE SWITCH

5930-01-026-6361 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: 42D300, 160C9509161, 160C950916-1, 5930-01-026-6361, 01-026-6361, 5930010266361, 010266361

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 28, 197601-026-636100206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR

Cross Reference | NSN 5930-01-026-6361
Part Number Cage Code Manufacturer
42D30009049CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY
160C950916-126512NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS
Technical Data | NSN 5930-01-026-6361
Characteristic Specifications
STYLE DESIGNATOR7 RECTANGULAR
OVERALL LENGTH4.000 INCHES MAXIMUM
BODY LENGTH0.570 INCHES NOMINAL
OVERALL DIAMETER2.500 INCHES MAXIMUM
PRESSURE SWITCH TYPE DIFFERENTIAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGBB4.00 ACTUATION POINT NOMINAL AND BB1.00 DEACTUATION POINT NOMINAL AND BB3.00 DIFFERENTIAL POINT NOMINAL
OPERATING TEMP RATING-67.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED LIQUID
PROOF PRESSURE120.00 POUNDS PER SQUARE INCH
TERMINAL TYPE WIRE LEAD
MOUNTING METHOD BASE
SENSING ELEMENT BURST PRESSURE180.00 POUNDS PER SQUARE INCH