NSN 5930-01-038-1482

Part Details | THERMOSTATIC SWITCH

5930-01-038-1482 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 860330364B00, 860-330364B-00, A303649, A30-3649, A303649, A30-3649, 860330364B00, 860-330364B00, 5930-01-038-1482, 01-038-1482, 5930010381482, 010381482

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAR 31, 197701-038-148200451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-038-1482
Part Number Cage Code Manufacturer
860-330364B-0042574CRYSTAL TIPS INC
A30-364950992RANCO INCRANCO CONTROLS DIV
A30-364949742RANCO MANAGEMENT CORP
860-330364B0000527SNYDERGENERAL CORPCOMMERCIAL PRODUCTS GROUP
Technical Data | NSN 5930-01-038-1482
Characteristic Specifications
OVERALL LENGTH2.567 INCHES NOMINAL
OVERALL HEIGHT1.660 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS DECREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAF50.00 ACTUATION POINT NOMINAL AND AF45.50 DEACTUATION POINT NOMINAL
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE
CAPILLARY TUBE LENGTH36.0 INCHES MINIMUM AND 39.0 INCHES MAXIMUM
TERMINAL TYPE QUICK DISCONNECT, MALE
MOUNTING METHOD BRACKET AND THREADED HOLE
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS2.179 INCHES MINIMUM AND 2.195 INCHES MAXIMUM
FEATURES PROVIDED ELECTRICAL ACCESS PORT
END ITEM IDENTIFICATIONICE MAKING MACHINE