NSN 5930-01-048-7541
Part Details | PRESSURE SWITCH
5930-01-048-7541 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 211C24311, 211C243-11, R211C2433, R211C243-3, 211C24311, 211C243-11, 5930-01-048-7541, 01-048-7541, 5930010487541, 010487541
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | OCT 03, 1977 | 01-048-7541 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL

Cross Reference | NSN 5930-01-048-7541
Part Number | Cage Code | Manufacturer |
---|---|---|
211C243-11 | 02750 | EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION |
R211C243-3 | 02750 | EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION |
211C243-11 | 06743 | GOULD INCFOIL DIV |
Technical Data | NSN 5930-01-048-7541
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 1 CYLINDRICAL |
OVERALL LENGTH | 2.180 INCHES MAXIMUM |
WIDTH ACROSS FLATS | 1.125 INCHES NOMINAL |
BODY LENGTH | 1.750 INCHES NOMINAL |
OVERALL DIAMETER | 1.125 INCHES NOMINAL |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BD1300.00 ACTUATION POINT MINIMUM AND BD1500.00 ACTUATION POINT MAXIMUM AND BD200.00 DEACTUATION POINT MINIMUM AND BD600.00 DEACTUATION POINT MAXIMUM |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 165.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
PROOF PRESSURE | 3000.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | WIRE LEAD |
MOUNTING METHOD | INLET CONNECTION |
FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
SENSING ELEMENT BURST PRESSURE | 5000.00 POUNDS PER SQUARE INCH |