NSN 5930-01-049-1337
Part Details | THERMOSTATIC SWITCH
5930-01-049-1337 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 10054658102, 10054658-102, 20600DL9015, 20600DL90-1-5, 5930-01-049-1337, 01-049-1337, 5930010491337, 010491337
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | OCT 12, 1977 | 01-049-1337 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-01-049-1337
Part Number | Cage Code | Manufacturer |
---|---|---|
10054658-102 | 94580 | HONEYWELL INTERNATIONAL INC.DBA HONEYWELL |
20600DL90-1-5 | 01295 | TEXAS INSTRUMENTS INCORPORATEDDBA TEXAS INSTRUMENTS |
Technical Data | NSN 5930-01-049-1337
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 4 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 2.000 INCHES NOMINAL |
OVERALL HEIGHT | 1.480 INCHES NOMINAL |
BODY DIAMETER | 0.920 INCHES NOMINAL |
BODY HEIGHT | 1.080 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AF85.00 ACTUATION POINT MINIMUM AND AF95.00 ACTUATION POINT MAXIMUM AND AF70.00 DEACTUATION POINT MINIMUM AND AF80.00 DEACTUATION POINT MAXIMUM |
OPERATING TEMP RATING | -70.0 DEG FAHRENHEIT MINIMUM AND 95.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TEMP SENSING ELEMENT TYPE | DISC |
TERMINAL TYPE | QUICK DISCONNECT, MALE |
MOUNTING METHOD | FLANGE AND SLOT |
MOUNTING SLOT WIDTH | 0.170 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.560 INCHES NOMINAL |
FEATURES PROVIDED | AUTOMATIC RESET |