NSN 5930-01-090-5405

Part Details | PRESSURE SWITCH

5930-01-090-5405 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: 326544P01, 326544P01, 1193P24, 326544P01, 5930-01-090-5405, 01-090-5405, 5930010905405, 010905405

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59FEB 21, 198001-090-540500206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL

Cross Reference | NSN 5930-01-090-5405
Part Number Cage Code Manufacturer
326544P018Z296DANFOSS FLUID POWER INCEASLEY OPN
326544P0133654HOWDEN FLUID SYSTEMS
1193P2498087ITT AEROSPACE CONTROLS LLCDBA ITT AEROSPACE CONTROLS UNIT S
326544P0158163MEGGITT (NORTH HOLLYWOOD), INC.DBA MEGGITT CONTROL SYSTEMS
Technical Data | NSN 5930-01-090-5405
Characteristic Specifications
STYLE DESIGNATOR1 CYLINDRICAL
OVERALL LENGTH2.300 INCHES MAXIMUM
WIDTH ACROSS FLATS0.680 INCHES NOMINAL
BODY LENGTH1.740 INCHES NOMINAL
OVERALL DIAMETER0.680 INCHES NOMINAL
PRESSURE SWITCH TYPE ABSOLUTE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGBC280.00 ACTUATION POINT NOMINAL AND BC200.00 DEACTUATION POINT NOMINAL AND BC80.00 DIFFERENTIAL POINT NOMINAL
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED LIQUID
PROOF PRESSURE300.00 POUNDS PER SQUARE INCH ABSOLUTE
TERMINAL TYPE CONNECTOR, RECEPTACLE
MOUNTING METHOD CLAMP
FEATURES PROVIDED HERMETICALLY SEALED CASE
SENSING ELEMENT BURST PRESSURE420.00 POUNDS PER SQUARE INCH ABSOLUTE
END ITEM IDENTIFICATIONR-114