NSN 5930-01-102-2772
Part Details | THERMOSTATIC SWITCH
5930-01-102-2772 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 24389063, 2438906-3, 171000M0D3130DEGFPORM5DEG2DEG, 17100-0-M0D3-130DEGFPORM5DEG2DEG, 171000MOD3130DEGFP5DEGFM2DEGF, 17100-0-MOD3-130DEGFP5DEGFM2DEGF, 171000MOD3130DEGFP5DEGFM2DEGF, 17100-0-MOD3-130DEGFP5DEGFM2DEGF, 5930-01-102-2772, 01-102-2772, 5930011022772, 011022772
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | OCT 16, 1980 | 01-102-2772 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-102-2772
Part Number | Cage Code | Manufacturer |
---|---|---|
2438906-3 | 55972 | HONEYWELL INTL INCDEFENSE AVIONICS SYSTEMS |
17100-0-M0D3-130DEGFPORM5DEG2DEG | 73168 | KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS |
17100-0-MOD3-130DEGFP5DEGFM2DEGF | 73168 | KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS |
17100-0-MOD3-130DEGFP5DEGFM2DEGF | 0KDP7 | KIDDE-FENWAL, INC.DBA KIDDE FIRE SYSTEM |
Technical Data | NSN 5930-01-102-2772
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 4.656 INCHES MINIMUM AND 4.906 INCHES MAXIMUM |
BODY DIAMETER | 0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CONTACT ADJUSTMENT RANGE | +128.00 TO +135.00 ACTUATION POINT DEGREES FAHRENHEIT AND +128.00 TO +135.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB |
CONTACT STIMULUS RATING | AF130.00 ACTUATION POINT NOMINAL AND AF2.00 DIFFERENTIAL POINT MINIMUM AND AF5.00 DIFFERENTIAL POINT MAXIMUM |
OPERATING TEMP RATING | -100.0 DEG FAHRENHEIT MINIMUM AND 400.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | WIRE LEAD |
MOUNTING METHOD | THREADED BUSHING |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND WEATHERPROOF |
END ITEM IDENTIFICATION | F/TF-15A ACFT 76301 |