NSN 5930-01-110-7094
Part Details | PRESSURE SWITCH
5930-01-110-7094 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: PSF100A6210, PSF100A-6210, PSF100A6210, PSF100A-6210, 114576902, 11457690-2, 114576902, 11457690-2, 5930-01-110-7094, 01-110-7094, 5930011107094, 011107094
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | APR 04, 1981 | 01-110-7094 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL

Cross Reference | NSN 5930-01-110-7094
Part Number | Cage Code | Manufacturer |
---|---|---|
PSF100A-6210 | 60426 | GENESIS LAMP CORP. |
PSF100A-6210 | 06141 | L3 AVIATION PRODUCTS, INC. |
11457690-2 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
11457690-2 | 0C579 | WORLD MAGNETICS COMPANY |
Technical Data | NSN 5930-01-110-7094
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 8 CYLINDRICAL |
OVERALL LENGTH | 1.760 INCHES NOMINAL |
OVERALL HEIGHT | 0.480 INCHES NOMINAL |
OVERALL WIDTH | 1.000 INCHES NOMINAL |
BODY LENGTH | 1.000 INCHES NOMINAL |
PRESSURE SWITCH TYPE | DIFFERENTIAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AR1.20 ACTUATION POINT MINIMUM AND AR1.80 ACTUATION POINT MAXIMUM AND AR1.20 DEACTUATION POINT MAXIMUM |
OPERATING TEMP RATING | -45.6 DEG CELSIUS MINIMUM AND 70.0 DEG CELSIUS MAXIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TERMINAL TYPE | QUICK DISCONNECT, FEMALE |
MOUNTING METHOD | BASE AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.145 INCHES MINIMUM AND 0.152 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.709 INCHES MINIMUM AND 0.729 INCHES MAXIMUM |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.709 INCHES MINIMUM AND 0.729 INCHES MAXIMUM |
SENSING ELEMENT BURST PRESSURE | 8.00 POUNDS PER SQUARE INCH GAGE |