NSN 5930-01-121-0956

Part Details | LIQUID LEVEL SWITCH

5930-01-121-0956 A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY.

Alternate Parts: F75634, F-75634, 5930-01-121-0956, 01-121-0956, 5930011210956, 011210956

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 30, 198101-121-095637187 ( SWITCH, LIQUID LEVEL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-121-0956
Part Number Cage Code Manufacturer
F-7563497424AMETEK INC.DBA AMETEK AEROSPACE & DEFENSE
Technical Data | NSN 5930-01-121-0956
Characteristic Specifications
DC VOLTAGE RATINGA28.0 VOLTS
INTERNAL BATTERY ACCOMMODATION NOT INCLUDED
CURRENT RATING AT MAXIMUM RATED VOLTAGE0.5 AMPERES NOMINAL LOAD
MAXIMUM CURRENT RATING0.5 AMPERES NOMINAL LOAD
VOLTAGE RATING AT MAXIMUM RATED CURRENT28.0 VOLTS
CONTACT ARRANGEMENTSINGLE THROW,SINGLE BREAK,NORMALLY CLOSED
ELECTRICAL CONNECTION TYPE CONNECTOR RECEPTACLE
CONNECTOR MANUFACTURER CODE50625
CONNECTOR IDENTIFICATIONS-29711-1
RELAY NOT INCLUDED
LIQUID TYPE FOR WHICH DESIGNEDD$DDF
OPERATING TEMP RATING28.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM
ACTUATION METHOD BUOYANCY
FLOAT QUANTITY1
MOUNTING POSITION VERTICAL
MOUNTING METHOD FLANGE
MOUNTING DIMENSIONSMTD BY FOUR 0.405 IN. MIN,0.412 IN. MAX DIA HOLES EQUALLY SPACED ON A 2.375 IN. DIA BOLT CIRCLE
OVERALL DIAMETER2.969 INCHES NOMINAL
TANK INSERTION LENGTH6.750 INCHES MINIMUM AND 7.000 INCHES MAXIMUM
SPECIFIC EQUIPMENT ACCOMMODATEDMULTI-HULL WATER CRAFT