NSN 5930-01-122-1001
Part Details | THERMOSTATIC SWITCH
5930-01-122-1001 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 29389421, 2938942-1, VE3186, VE-3186, 5930-01-122-1001, 01-122-1001, 5930011221001, 011221001
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | NOV 14, 1981 | 01-122-1001 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-122-1001
Part Number | Cage Code | Manufacturer |
---|---|---|
2938942-1 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
VE-3186 | 93929 | SPX CORPORATIONDBA RADIODETECTION |
Technical Data | NSN 5930-01-122-1001
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 1.250 INCHES NOMINAL |
OVERALL HEIGHT | 0.690 INCHES NOMINAL |
OVERALL WIDTH | 0.380 INCHES MAXIMUM |
BODY LENGTH | 0.750 INCHES NOMINAL |
BODY HEIGHT | 0.450 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AF165.00 ACTUATION POINT NOMINAL AND AF160.00 DEACTUATION POINT NOMINAL |
OPERATING TEMP RATING | 1.0 DEG CELSIUS MAXIMUM AND -54.0 DEG CELSIUS MINIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB, SOLDER LUG |
MOUNTING METHOD | FLANGE AND SLOT |
MOUNTING SLOT WIDTH | 0.125 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.000 INCHES NOMINAL |
END ITEM IDENTIFICATION | OE236DELTA81 |