NSN 5930-01-128-3726
Part Details | PRESSURE SWITCH
5930-01-128-3726 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: M939539AK7J7, M9395/39-AK7J7, MILS939539, MIL-S-9395/39, 5930-01-128-3726, 01-128-3726, 5930011283726, 011283726
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAR 20, 1982 | 01-128-3726 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-01-128-3726
Part Number | Cage Code | Manufacturer |
---|---|---|
M9395/39-AK7J7 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-S-9395/39 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-01-128-3726
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 5 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 1.500 INCHES NOMINAL |
OVERALL HEIGHT | 2.920 INCHES NOMINAL |
OVERALL WIDTH | 1.120 INCHES NOMINAL |
BODY HEIGHT | 0.500 INCHES NOMINAL |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BB25.00 ACTUATION POINT NOMINAL AND BB20.00 DEACTUATION POINT NOMINAL AND BB5.00 DIFFERENTIAL POINT NOMINAL |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
PROOF PRESSURE | 270.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | INPUT PORT |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
TEST DATA DOCUMENT | 81349-MIL-S-9395 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL--9395 TO 39 GOVERNMENT SPECIFICATION |
SENSING ELEMENT BURST PRESSURE | 800.00 POUNDS PER SQUARE INCH |
END ITEM IDENTIFICATION | FUSELAGE |