NSN 5930-01-129-4552

Part Details | THERMOSTATIC SWITCH

5930-01-129-4552 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: M522N223A253, 563069001, 563069-001, 31458461, 3145846-1, 11041312, 11041-3-12, 5930-01-129-4552, 01-129-4552, 5930011294552, 011294552

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59APR 07, 198201-129-455200451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-01-129-4552
Part Number Cage Code Manufacturer
M522N223A25397896HONEYWELL INTERNATIONAL INC.DBA HONEYWELL
563069-00156232LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
3145846-110001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
11041-3-1282647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
Technical Data | NSN 5930-01-129-4552
Characteristic Specifications
STYLE DESIGNATOR4 CYLINDRICAL W/FLANGE
OVERALL LENGTH1.074 INCHES MINIMUM AND 1.206 INCHES MAXIMUM
OVERALL HEIGHT0.500 INCHES MAXIMUM
BODY DIAMETER0.642 INCHES MAXIMUM
BODY HEIGHT0.280 INCHES MINIMUM AND 0.395 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAF243.00 ACTUATION POINT MINIMUM AND AF263.00 ACTUATION POINT MAXIMUM AND AF215.00 DEACTUATION POINT MINIMUM AND AF231.00 DEACTUATION POINT MAXIMUM
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 500.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNEDQ$DADF
TEMP SENSING ELEMENT TYPE DISC
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.113 INCHES MINIMUM AND 0.121 INCHES MAXIMUM
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.807 INCHES MINIMUM AND 0.815 INCHES MAXIMUM
FEATURES PROVIDED HERMETICALLY SEALED CASE