NSN 5930-01-185-1323
Part Details | PRESSURE SWITCH
5930-01-185-1323 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: M939530XQINU, M9395/30-XQINU, MILS939530, MIL-S-9395/30, 5930-01-185-1323, 01-185-1323, 5930011851323, 011851323
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JUL 25, 1984 | 01-185-1323 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-01-185-1323
Part Number | Cage Code | Manufacturer |
---|---|---|
M9395/30-XQINU | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-S-9395/30 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-01-185-1323
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 7 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 3.000 INCHES MINIMUM AND 3.250 INCHES MAXIMUM |
BODY DIAMETER | 1.500 INCHES MAXIMUM |
OVERALL DIAMETER | 1.500 INCHES MAXIMUM |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AF1500.00 ACTUATION POINT NOMINAL AND AF1300.00 DEACTUATION POINT NOMINAL AND AF200.00 DIFFERENTIAL POINT NOMINAL |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | COMPONENT SOCKET |
MOUNTING METHOD | CLAMP |
TEST DATA DOCUMENT | 81349-MIL-S-9395 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL--9395 TO 30 GOVERNMENT SPECIFICATION |
SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |