NSN 5930-01-224-6558
Part Details | PRESSURE SWITCH
5930-01-224-6558 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 300900006, 300-900-006, 300900006, 300-900-006, 20PS6621, 20PS66-21, 5930-01-224-6558, 01-224-6558, 5930012246558, 012246558
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 19, 1986 | 01-224-6558 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-01-224-6558
Part Number | Cage Code | Manufacturer |
---|---|---|
300-900-006 | 62842 | ALLIED HEALTHCARE PRODUCTS, INC. |
300-900-006 | 62002 | LIFE SUPPORT PRODUCTS INC |
20PS66-21 | 14859 | TEXAS INSTRUMENTS INCCONTROL PRODUCTS DIV |
Technical Data | NSN 5930-01-224-6558
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 8 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 2.110 INCHES NOMINAL |
BODY LENGTH | 1.060 INCHES NOMINAL |
OVERALL DIAMETER | 0.880 INCHES NOMINAL |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BD30.00 ACTUATION POINT NOMINAL AND BD20.00 DEACTUATION POINT NOMINAL |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
PROOF PRESSURE | 600.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | TAB W/SCREW |
MOUNTING METHOD | INPUT PORT |
SENSING ELEMENT BURST PRESSURE | 3500.00 POUNDS PER SQUARE INCH GAGE |