NSN 5930-01-287-0014

Part Details | THERMOSTATIC SWITCH

5930-01-287-0014 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 100TC54CC3A, 100TC5-4CC3A, 100TC5DCC3A, 100TC5-DCC3A, 5930-01-287-0014, 01-287-0014, 5930012870014, 012870014

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 13, 198801-287-001400451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR

Cross Reference | NSN 5930-01-287-0014
Part Number Cage Code Manufacturer
100TC5-4CC3A98087ITT AEROSPACE CONTROLS LLCDBA ITT AEROSPACE CONTROLS UNIT S
100TC5-DCC3A98087ITT AEROSPACE CONTROLS LLCDBA ITT AEROSPACE CONTROLS UNIT S
Technical Data | NSN 5930-01-287-0014
Characteristic Specifications
STYLE DESIGNATOR3 RECTANGULAR
OVERALL LENGTH3.500 INCHES NOMINAL
OVERALL HEIGHT6.600 INCHES MAXIMUM
OVERALL WIDTH2.850 INCHES MAXIMUM
BODY HEIGHT3.500 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+60.00 TO +205.00 ACTUATION POINT DEGREES FAHRENHEIT AND +40.00 TO +200.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT HEX NUT AND INTERNAL DEACTUATION POINT HEX NUT
OPERATING TEMP RATING-40.0 DEG FAHRENHEIT MINIMUM AND 180.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED LIQUID
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH72.0 INCHES NOMINAL
BULB LENGTH4.500 INCHES MAXIMUM
BULB DIAMETER0.375 INCHES NOMINAL
TERMINAL TYPE WIRE LEAD
MOUNTING METHOD BASE AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.265 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION DIAGONAL
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.720 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS2.720 INCHES NOMINAL
FEATURES PROVIDED ELECTRICAL ACCESS PORT
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION CORROSION RESISTANT