NSN 5930-01-342-6730
Part Details | PRESSURE SWITCH
5930-01-342-6730 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: M939526ESD, M9395/26-ESD, MILS939526, MIL-S-9395/26, 5930-01-342-6730, 01-342-6730, 5930013426730, 013426730
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JUL 29, 1991 | 01-342-6730 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL

Cross Reference | NSN 5930-01-342-6730
Part Number | Cage Code | Manufacturer |
---|---|---|
M9395/26-ESD | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-S-9395/26 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-01-342-6730
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 1 CYLINDRICAL |
OVERALL LENGTH | 2.325 INCHES NOMINAL |
WIDTH ACROSS FLATS | 0.688 INCHES MINIMUM AND 1.000 INCHES MAXIMUM |
BODY LENGTH | 1.545 INCHES NOMINAL |
OVERALL DIAMETER | 0.995 INCHES MINIMUM AND 1.150 INCHES MAXIMUM |
PRESSURE SWITCH TYPE | ABSOLUTE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BC42.50 ACTUATION POINT NOMINAL AND BC38.10 DEACTUATION POINT NOMINAL |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
PROOF PRESSURE | 120.00 POUNDS PER SQUARE INCH ABSOLUTE |
TERMINAL TYPE | WIRE HOOK |
MOUNTING METHOD | INPUT PORT |
TEST DATA DOCUMENT | 81349-MIL-S-9395 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL--9395 TO 26 GOVERNMENT SPECIFICATION |
SENSING ELEMENT BURST PRESSURE | 800.00 POUNDS PER SQUARE INCH ABSOLUTE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |